Main Maker

AG Associates Heatpulse 4100 Rapid Thermal Processing System

AG Associates Heatpulse 4100 Utility Specification

AG Associates Heatpulse 4100 Utility Specification:

The following table is a summary of the utility specifications for the Heatpulse 8108 system:

UTILITY Flow Rate Pressure
Tube Cooling CDA or Utility N2 8 SCFM 10 SCFM 15 SCFM 30 psi 60 psi 100 psi
Valve Actuation CDA or Utility N2 <1 SCFM <1 SCFM <1 SCFM 70 psi 80 psi 100 psi
Cooling Water Supply 1.6GPM 2.0 GPM 2.5GPM 30 psi 40 psi 100 psi
Cooling Water Return 1.6 GPM 2.0 GPM 2.5 GPM 20 psi 30 psi 40 psi
Gas Box Exhaust 0 SCFM 150 SCFM >200 SCFM .5″ H2O .75″ H2O ——–
Cooling Exhaust 8 SCFM 10 SCFM 15 SCFM .5″ H2O .75″ H2O ——–
Scavenger Hood Exhaust 20 SCFM 25 SCFM 30 SCFM .5″ H2O .75″ H2O ——–
Containment Exhaust (Optional) 0 SCFM 0 SCFM 2 SCFM .5″ H2O .75″ H2O ——–
Exhaust Manifold Outlet 28 SCFM 35 SCFM 45 SCFM .5″ H2O .75″ H2O ——–
Process Gas Exhaust (Scrubber) 10 SCFM 10 SCFM 10 SCFM .5″ H2O .75″ H2O 2.5″ H2O
Process Gas Supply 10 SCFM 10 SCFM 10 SCFM 30 psi 40 psi 60 psi
Recirculator Water Supply 3 GPM 5 GPM 7 GPM 10 psi 20 psi 40 psi

 

The trademarks of the equipment and parts contained in this website belonged to the Original Equipment Manufacturers