Model: Hitachi S 5000 FE-SEM

  • Ultra High Resolution
  • Accelerating Voltage: 30 kV
  • Magnification: 500,000x
  • Performance
    Image Resolution: 0.6 nm (at 30 kV),3.5 nm (at 1 kV) in secondary electron image
  • Magnification
    Low mag mode: x30 ~ x500
    High mag mode: x250 ~ x800,000
  • Electron Optics
    Electron Gun: Cold field emission source
    Accelerating Voltage: 0.5 ~ 30 kV (0.1 kV/step)
    Lens System: 3 stage electromagnetic stage
    Objective Operture:4 openings, selectable and alignable from outside of vacuum, anticontamination heater built in
    Stigmator: Octapole electromagnetic type (X, Y)
    Scanning Coil: 2 stage electromagnetic
  • Specimen Stage
    System: side entry type
    Motion:
    X = +/- 3.5 mm (continuous)
    Y = +/- 2 mm (continuous)
    Tilt = +/- 40 Degrees (continuous)
    Tilt range is restricted by optional specimen holders and optional detectors
    Specimen Size: 9.5 mm x 5 mm x 2.4 mm (h) for standard holder, 20 mm x 6 mm x 2.4 mm (h) (maximum) for larger specimen holder
  • Specimen Exchange: Airlock type with prepumping
  • Display System
    Imaging Signal: Secondary electron image Back scatted electron image (option), X-ray image option
    Scan Model: Normal scan, reduced area, line scan, photos scan, spot position, analysis scan, dual mag/split screen, oblique
    CRT: 12 inch monitor for viewing x 2 sets, (12 inch color monitor at option), 7 inch photo recording/ultra high resolution monitor x 1 set
    Frame Memory: 1, 024 x 1,024 pixel memory x 2 sets for slow scan image (4-split screen image can be recorded), 512 x 512 pixel x 1 set for viewing
    Image Processing: Auto image brightness and contrast, gamma control, dynamic stigmator monitor, auto sigmator, dynamic focus, auto focus
    Scan Speed: TV, 0.3, 2, 10 (9), 20 (25) s/frame for viewing, 40 (35), 80 (100), 160, 320 s/frame for recording, ( ): for 60 Hz line frequency operation
    Electrical Image Shift: +/- 3 μm
    Auto Data Display: Film number, accelerating voltage, micron bar, micron scale, magnification, and date are printed on film automatically
  • Vacuum System
    Vacuum Pumps:
    IP1: 60 1/s
    IP2: 20 1/s
    IP3: 20 1/s
    TMP: 340 1/s
    RP: 140 1/min (168 1/min) x 2 sets, ( ): for 60 Hz line frequency operation
    Security
    The instrument is protected against power and vacuum failures
  • Standard Equipment
    Column (x1)
    Display unit (x1)
    Power supply (x1)
    S-5080 Camera (x1)
    Air compressor (x1)
    Rotary pumps (x2)
    Standard tool (1 set)
    Spares and Consumables (1 set)
    Instruction manual (x1)
    Auto transformer (x1)
  • Dimensions and Weight:
    Column: 89(w) x 103(d) x 160(h) cm, 385 kg
    Display: 110(w) x 90 (d) x 116 (h) cm, 235 kg
    Power Supply: 54(w) x 63(d) x 150(h) cm, 215kg (Ion pump power supply, TMP power supply, stage control power supply, lens power supply)
    Rotary Pump: 54(w) x 22(d) x 41(h) cm, 32 kg x 2 sets
    Weight: 20(w) x 18(d) x 16(h) cm, 40 kg
    Air Compressor: 40(w) x 23(d) x 55(h) cm, 18 kg
    Auto Transformer: 33(w) x 35(d) x 38(h) cm, 72 kg
  • 1998 Vintage

Quantity:  1 set

Location: FOX-SS5816-20250204

Valid: Subject to prior sale without notice. This is only for end users. Applicate your time.

Condition: Used.  We sell it at AS IS WHERE IS.

The trademarks of the equipment and parts contained in this page belonged to the Original Equipment Manufacturers.

Please contact us for more information on the product:

[dynamichidden dynamichidden-813 "CF7_URL"]

Your Name*:

Your Email:

Your Message:

Captchac Codecaptcha

Submit:

The trademarks of the equipment and parts contained in this website belonged to the Original Equipment Manufacturers